
Tamperloks
Neopharma Technologies Tamperloks drug testing cup is the new global benchmark in drugs of abuse urine testing technology
Interlocking lid and seal to ensure the device is not tampered with after sample is collected, and can be safely sent to the lab for a confirmatory testing
Unique triple chamber design ensures device is 100% LEAK and ODOUR proof to ensure hygiene and minimize risk of compromising the sample during transportation and preventing retesting
Temperature test strip to ensure that the sample collected is a fresh sample
Adulteration strip is part of the test to ensure the sample is not compromised
Interlocking ring is included to ensure that the device is not accidentally locked before use
Digitally enabled by the NEOVAULT app, which is available for download via apple and google
Unique dynamic QR code with a serial number
Fully integrated with the NEOVAULT ERP software platform providing electronic CHAIN OF CUSTODY and digital reporting

→ DRUID®
The TamperLoks Drug Testing Device is a tamperproof lateral flow chromatographic immunoassay for the detection of drugs of abuse and drugs of abuse metabolites in urine. All drug test strips assembled in the TamperLoks Device will be as specified by the user. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug test result, particularly when preliminary positive results are indicated. The device is for professional use.
→ Principle
The TamperLoks Drug Testing Device is an immunoassay based on the principle of competitive binding. Drugs of abuse which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody. During testing, the urine specimen migrates upward through capillary action. The drugs, if present in the urine specimen below its cut-off concentration, will not saturate the binding sites of its specific antibody. The antibody will then react with the drug-protein conjugate and a visible colored line will appear in the test line above the specific drug test strip. The presence of drugs above the cut-off concentration will saturate all the binding sites of the antibody. Therefore, the colored line will not form in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating the proper volume of specimen has been added and membrane wicking has occurred.
→ Interpretation of results

POSITIVE: One red line appears in the control region (C). No line appears in the test region (T). This positive result indicates the drug concentration is above the detectable level. Please refer to the Illustration above.
NEGATIVE: Two lines appear. One red line should be in the control region (C), and another red or weak pink line adjacent appears in the test region (T). This negative result indicates the drug concentration is below the detectable level.
*NOTE: The shade of red in the test line region (T) may vary, but it should be considered negative whenever there is even a faint pink line. Please refer to the Illustration above.
INVALID: Control line fails to appear. Incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test device. If the problem persists, discontinue using the lot immediately and contact your local distributor. Please refer to the Illustration above. The results can be read for a period of up to 10 minutes. DO NOT INTERPRET RESULTS AFTER 10 MINUTES as they will no longer be valid.





Perth, Australia
Utah, USA
Kuala Lumpur, Malaysia
© 2026 Neopharma Technologies. All Rights Reserved
Privacy Policy